{"id":21153,"date":"2026-11-15T20:32:22","date_gmt":"2026-11-15T19:32:22","guid":{"rendered":"https:\/\/navier-lab.fr\/?p=21153"},"modified":"2026-11-15T20:34:28","modified_gmt":"2026-11-15T19:34:28","slug":"thesis-defense-karen-mourda","status":"publish","type":"post","link":"https:\/\/navier-lab.fr\/en\/thesis-defense-karen-mourda\/","title":{"rendered":"Thesis defense \u2013 Karen Mourda"},"content":{"rendered":"<p>Karen Mourda, PhD student in the Rheophysics &amp; Porous Media team at the Navier laboratory, will defend their thesis entitled &#8220;<em>Effective thermal conductivity of bio-based fibrous insulation materials: Effects of porosity, fiber orientation and moisture<\/em>&#8221; on Monday, November 23, 2026 at 10:30 AM, at Amphith\u00e9\u00e2tre Bienven\u00fce, Universit\u00e9 Gustave Eiffel, 14-20 boulevard Newton, 77420 Champs-sur-Marne.<\/p>\n<p>The defense will be held in french.<\/p>\n<p>The defense will be broadcast at the following link: https:\/\/univ-eiffel.zoom.us\/j\/83731364642<br \/>\nID de r\u00e9union : 837 3136 4642<br \/>\nMot de passe : F5NeVYX2<\/p>\n<p style=\"text-align: justify;\">The thesis jury consists of the following members:<\/p>\n<ul style=\"list-style: none; margin: 0; padding: 0;\">\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>Didier Defer, Universit\u00e9 d&#8217;Artois, Reviewer<\/li>\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>Thibault Colinart, Universit\u00e9 Bretagne Sud, Reviewer<\/li>\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>St\u00e9phanie Bonnet, Universit\u00e9 de Nantes, Examiner<\/li>\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>No\u00e9mie Prime, Universit\u00e9 de Savoie Mont Blanc, Examiner<\/li>\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>Cl\u00e9mence Gaunaud, Saint Gobain, Examiner<\/li>\n<li style=\"margin: 0 0 0.5em 0;\"><span style=\"color: #e2a034; margin-right: 0.5em;\">\u25cf<\/span>Phillipe Coussot, Universit\u00e9 Gustave Eiffel, Director<\/li>\n<\/ul>\n<style>\n.resume-toggle summary::-webkit-details-marker{display:none;}<br \/>.resume-toggle summary{list-style:none;}<br \/>.resume-toggle .resume-arrow{display:inline-block;transition:transform .15s ease;}<br \/>.resume-toggle[open] .resume-arrow{transform:rotate(90deg);}<br \/><\/style>\n<details class=\"resume-toggle\">\n<summary style=\"cursor: pointer; color: #1e73be; font-weight: 600;\"><span class=\"resume-arrow\">\u25b8<\/span> Abstract<\/summary>\n<p style=\"text-align: justify;\">Natural-fiber-based building insulation materials (hemp, flax, cellulose, etc.) are increasingly used, notably because of their low thermal conductivity and their ability to regulate moisture. However, the thermal conductivities observed vary widely depending on the material and its conditioning. The objective of this thesis is to investigate to what extent this variability can be rationalized using a limited number of physically relevant parameters.<br \/>\nBecause the thermal characterization of these materials can be strongly affected by artefacts such as heat losses and swelling, we first develop a measurement procedure based on heat-flow-meter measurements with a low temperature gradient and a large aspect ratio, allowing reliable thermal-conductivity measurements to be obtained. By varying the porosity of the investigated materials (cellulose, hemp and human hair) and the fiber orientation through compression over very broad ranges, we then show that the key parameters governing the thermal conductivity of dry materials in a generic manner are their porosity and mean fiber orientation. A simple model is proposed to explain this behavior. Finally, we show that it is essential to distinguish the direct effect of moisture from the moisture-induced change in material volume. At comparable porosity, the highly humid state is found to be, on average, approximately 23% more conductive in the direction perpendicular to the mean fiber orientation. By contrast, the effect of moisture in the parallel direction is negligible, revealing an additional moisture-sensitive structural contribution.<br \/>\nOverall, this work identifies porosity, mean fiber orientation and moisture state as the main variables governing heat transfer in bio-based fibrous insulation materials, while fiber-specific characteristics play a secondary role.<\/p>\n<\/details>\n","protected":false},"excerpt":{"rendered":"<p>Karen Mourda, PhD student in the Rheophysics &amp; Porous Media team at the Navier laboratory, will defend their thesis entitled &#8220;Effective thermal conductivity of bio-based fibrous insulation materials: Effects of porosity, fiber orientation and moisture&#8221; on Monday, November 23, 2026 at 10:30 AM, at Amphith\u00e9\u00e2tre Bienven\u00fce, Universit\u00e9 Gustave Eiffel, 14-20 boulevard Newton, 77420 Champs-sur-Marne. The [&hellip;]<\/p>\n","protected":false},"author":145,"featured_media":21154,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[266,251,290,299],"tags":[],"class_list":["post-21153","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-actualites-en","category-annonces-en","category-annonces-rmp-en","category-soutenances-de-these-en"],"acf":[],"_links":{"self":[{"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/posts\/21153","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/users\/145"}],"replies":[{"embeddable":true,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/comments?post=21153"}],"version-history":[{"count":1,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/posts\/21153\/revisions"}],"predecessor-version":[{"id":21156,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/posts\/21153\/revisions\/21156"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/media\/21154"}],"wp:attachment":[{"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/media?parent=21153"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/categories?post=21153"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/navier-lab.fr\/en\/wp-json\/wp\/v2\/tags?post=21153"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}